Materials:
Q:
What material are COPRO™ fittings made of?
A: The fittings are a forged brass (ASTM B-283), the gripping
ring is made of 316 stainless steel, and the o-ring is
EPDM pre-lubed with an NSF-61 approved lubricant.
Joining Tubing:
Q:
Do
I need to prep the ends differently than a solder joint?
A: As with sweat copper fittings, the tube must be chamfered,
deburred and reamed. COPRO™ recommends the Quick Fitting , Inc.
Prep Tool to chamfer, deburr and ream tube ends. These
steps are essential to ensure the proper connection of
your COPRO™ push-to-connect system. Also, be sure to draw
an inspector's mark on the tube to let the installer know
when the tube has been inserted far enough.
Q: What types of tubing can
COPRO™
be
used on?
A: COPRO™ is ideal for use with copper and stainless steel.
Consult factory for use with CPVC and PEX.
Installing, Testing and Flushing
Your COPRO™ System:
Q:
What have COPRO™ fittings been tested to?
A: COPRO™ fittings have been tested to 900 psi at 200 °F,
giving it a safety factor of over 4 to 1. The burst pressure
is over 1,500 psi.
Q: What support hanger spacing
must
I use
with
my COPRO™ System?
A: Support is identical to a sweat system and should adhere
to local codes. Always fully support heavy loads on your
COPRO™ System.
Q: How
do I test my COPRO™ System?
A: Pressure-test the same as you would with a copper sweat
system. Normal testing at 1 ½ times is permitted even
up to 300 psi.
Q: Do I need to lubricate the
joint
when
installing?
A: No. Engineered seals come factory-lubricated with an NSF-61
approved lubricant.
Q: Do I still have to flush
my
system?
A:
Yes, but the system will be cleaner and faster to flush
since there is no solder or flux.
Q: Is testing of my COPRO™ System
the same as testing a copper system?
A:
Yes, COPRO™ is tested the same way as a sweat copper system.
Adapting Your COPRO™ System
to Other Systems:
Q:
Are
valves and specialty items available for my COPRO™ push-to-connect
System?
A:
Yes, please see our product catalog for more information.
Q: Can I use my own valves?
A:
Yes, with two COPRO™ male threaded connectors.
Q: Can my COPRO™ System connect
with existing threaded systems?
A:
Yes, with the use of a COPRO™ male threaded connector.
Q: Can I solder directly into
a COPRO™ push-to-connect fitting or valve?
A:
No
COPRO™ Standards and Approvals:
Q:
Is the COPRO™ System NSF-61 approved?
A:
Yes.
Q: What approvals does COPRO™
have?
A:
Manufactured by the world’s originator and largest producer
of push-to-connect fittings, COPRO™ is certified to NSF-61.
Additional certifications include: British: BS EN 1294/BS
864 Part 2: Copper and copper alloys: Copper fittings,
British: WRAS approval, Netherlands: NF-EN 1254-1, German:
DVGW GW 8.
COPRO™ Uses and Restrictions:
Q:
Are
“pressure drops” and “friction loss” the same for a COPRO™
System and a copper sweat system?
A:
COPRO™ fittings are full bore fittings offering superior
flow characteristics. The pressure drops and friction
loss are very similar to sweat copper fittings.
Q: Can I rotate my COPRO™ push-to-connect
fittings?
A:
Yes, the fittings can be rotated 360 degrees while the
system is not under pressure.
Q: Can my COPRO™ System be installed
on wet or dry tube?
A:
Yes. COPRO™ fittings install on wet or dry tube. However,
you should always depressurize your system before installing
COPRO™ products.
COPRO™ Temperature and Pressure
Ratings:
Q:
What
working temperature/pressure is the COPRO™ System rated
for?
A:
180 °F and 200 PSI
For additional information,
please Contact Quick Fitting , Inc. through our online form or call toll free 877-238-4826.